Siemens Ceramic fuse MT 2A 400V AC 8.5x32mm 3NW6302-1
2 AProduct details
Siemens Digital Industrial Cylinder Fuse 3NW6302-1
Manufacturer: Siemens Digital Industrial
Designation: Cylinder fuse without indicator, size 8
Type: 3NW6302-1
Size: other
Voltage type: AC
Rated current: 2 A
Rated voltage: 400 V
Operating class: gL/gG (General-purpose line protection/General-purpose device protection)
Operating frequency: 45..62 Hz
Tripping characteristic: other
Cut-off capacity: 20 kA
Power loss at rated current: 2 W
Siemens Digital Industrial Cylinder Fuse 3NW6302-1: further details
SENTRON, cylinder fuse insert, 8x32 mm, 2 A, gG, Un AC: 400 V
SENTRON cylinder fuse system for selective plant protection. Siemens cylinder fuse inserts and fuse holders are suitable for use in industrial plants. They are standard in Europe and tested and approved as fuse disconnectors, but not intended for switching under load. For switching under load, Siemens offers a comprehensive portfolio, such as 3KF. The Siemens cylinder fuse systems are characterized primarily by:
1. Compliance with standards IEC 60269-1, -2, and -3.
2. Compliance with standard UL 512.
3. Quick fuse replacement due to space for spare fuses in the insert.
4. Rapid identification of the blown fuse through a blinking LED in case of tripping.
EAN: 4001869061863.
Item number | 33341888 |
Fuse type | Cylinder fuse |
Nominal current | 2 A |
breaking capacity | 20000 A |
Nominal voltage | 400 V |
voltage type | AC |
Country of origin | France |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 pcs. |
Diameter | 32 mm |
Product Safety |
30-day right of return if unopened
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Fuses» category have a defect within the first 24 months?
Source: Galaxus- 4.Hager0,1 %
- 4.Max Hauri0,1 %
- 6.Mersen0,2 %
- 7.Siemens0,5 %
- 8.Fusibles Lac0,6 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- SiemensNot enough data
- Beha AmprobeNot enough data
- Fusibles LacNot enough data
- GoobayNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Fuses» category returned?
Source: Galaxus- 4.Max Hauri1,7 %
- 5.Mersen1,8 %
- 6.Hager3 %
- 7.Tru Components5,3 %
- 8.Siemens7,4 %