Hager Helicopter 3 + N AC Switch B 10A 0.03A Type A 6kA Type RCBO (ADZ310D)
On this page you’ll find a ranking of the best Residual-current devices from Hager. To give you a quick overview, we’ve added the most important product details. This page always stays fresh and updates automatically.
Residual current circuit breaker 3X 1PN 6kA B-10A 30mA Type QuickConnect. Residual current circuit breaker according to DIN EN61009-1 VDE 0664-20 with a single-pole circuit breaker for 230 AC circuits and a residual current protection circuit in a compact housing. QuickConnect terminal according to DIN EN 60898-1 VDE 0641-11, with a load capacity of up to 16 A at the output and up to 63 A at the input, blue test button and residual current indicator. Easy individual removal from the phase rail assembly. Suitable for retrofitting additional devices. Labeling option directly on the device. ADZ310D.

Hager Helicopter 3 + N AC Switch B 10A 0.03A Type A 6kA Type RCBO (ADZ310D)
Hager Circuit Breaker MBN316
Manufacturer: Hager
Designation: 3-pole Circuit Breaker B-16A, 6kA
Type: MBN316
Installation Depth: 70 mm
Tripping Characteristic: B
Total Number of Poles: 3
Number of Protected Poles: 3
Rated Current: 16 A
Rated Voltage: 400 V
Rated Insulation Voltage Ui: 500 V
Rated Impulse Voltage Uimp: 4 kV
Type of Voltage: AC
Rated Switching Capacity Icn according to EN 60898 at 400 V: 6 kA
Rated Short-Circuit Capacity Icu according to IEC 60947-2 at 400 V: 10 kA
Frequency: 50..60 Hz
Power Loss: 6.33 W
Energy Limitation Class: 3
Flush Mounting: Yes
Switching Neutral Conductor: No
Overvoltage Category: 3
Degree of Pollution: 2
Additional Devices Possible: Yes
Width in Division Units: 3
Protection Class (IP): IP20
Ambient Temperature during Operation: -25..70 °C
Connectable Conductor Cross-Section Multi-Stranded: 1..25 mm²
Connectable Conductor Cross-Section Solid: 1..35 mm²
Explosion-Proof: No
Hager Circuit Breaker MBN316: Additional Details
3-pole circuit breaker with 6kA B-characteristic, 16A, 3 modules. Circuit breaker according to DIN EN 60898-1 (VDE 0641-11) with delayed thermal tripping for overload protection and electromagnetic tripping for short-circuit protection. Suitable for retrofitting additional devices. Labeling option directly on the device and individual removal from the phase rail connection by releasing the DIN rail quick fastening.

Hager RCD Switch CDA440D
Manufacturer: Hager
Designation: RCD Switch 4-pole 40A/30mA, 6kA
Type: CDA440D
Number of Poles: 4
Rated Voltage: 400 V
Rated Current: 40 A
Rated Residual Current: 0.03 A
Rated Insulation Voltage Ui: 500 V
Rated Impulse Voltage Uimp: 4 kV
Power Loss: 6.5 W
Mounting Type: DIN Rail
Residual Current Type: A
Selective Type: No
Time-Delayed Type: No
Short-Circuit Strength (Icw): 6 kA
Surge Current Strength: 0.25 kA
Voltage Type: AC
With Locking Mechanism: Yes
Frequency: 50 Hz
Additional Devices Possible: Yes
Protection Class (IP): IP20
Width in Division Units: 4
Installation Depth: 70 mm
Ambient Temperature During Operation: -25..40 °C
Degree of Pollution: 2
Connectable Conductor Cross-Section Multi-Wire: 1..16 mm²
Connectable Conductor Cross-Section Single-Wire: 1..25 mm²
RAL Number (similar): 7005
Explosion-Proof: No
Hager RCD Switch CDA440D: Additional Details
4-pole residual current circuit breaker 6kA 40A 30mA Type A. Residual current protective switch (RCD) according to DIN EN 61008-1 (VDE 0664-10), DIN EN 61008-2-1 (VDE 0664-11) with Bi-Connect terminals at the bottom, external blue test button, and residual current indicator. Suitable for retrofitting additional devices. Connection terminals with wire insertion protection, labeling option directly on the device.

Residual current circuit breaker according to DIN EN 61009-1 (VDE 0664-20) with QuickConnect connection, up to 20 A on the supply line and up to 63 A on the supply line, blue test button and residual current display. Easy individual removal from the phase busbar system. Suitable for retrofitting additional devices. Labeling option directly on the device.

Miniature circuit-breaker with QuickConnect terminal in accordance with DIN EN 60898-1 (VDE 0641 Part 11):2003-12 EN 60898-1:2003 EN 60898-1, pr A1:2003, on the outgoing circuit up to 16A and on the incoming circuit up to 63A. Protection against accidental contact to IP2x DIN VDE 0106 Part 100 with VDE symbol. LS with time-delayed thermal release for overload protection and electromagnetic release for short-circuit protection. Suitable for retrofitting additional equipment Labelling option directly on the device and individual removal from the phase busbar system by unlocking the top hat rail quick fastening.

Residual current circuit breaker 4P 6kA C-20A 30mA Type QCQB. Residual current circuit breaker according to DIN EN 61009-1 VDE 0664-20 with overload protection of the neutral conductor through a 4-pole circuit breaker for 400V three-phase circuits and a residual current protection circuit in a compact housing. QuickConnect spring-loaded terminal according to DIN EN 60898-1 VDE 0641-11, at the outgoing and incoming connections, blue test button and residual current indicator. Easy single removal from the phase rail connection using the top and bottom DIN rail sliders. Suitable for retrofitting additional devices. Labeling option directly on the device. ADM470QC.

Residual current circuit breaker, 10 kA, 63 A, 30 mA Type B. All-current sensitive residual current device (RCD), RCCB according to DIN EN 61008-1 VDE 0664-10, DIN EN 61008-2-1 VDE 0664-11, DIN EN 61543 VDE 0664-30, and DIN EN 62423 VDE 0664-40. Short-time delayed RCD for protection against smooth direct current and alternating current fault currents in the frequency range up to 100 kHz. The tripping within this frequency range up to 20 kHz occurs below 420 mA. Complies with the requirements of the installation standards DIN VDE 0100-410 and DIN VDE 0100-530. Suitable for retrofitting additional devices, tool-free installation. Connection terminals with Bi-Connect terminals at the bottom, blue test button, fault current indicator, Type B plus. Operational indicator, top and bottom DIN rail slider for easy installation. Labeling option directly on the device. CDB663D.

4-pole residual current circuit breaker 10kA 63A 100mA type S selective. Residual current circuit breaker (RCCB) according to DIN EN 61008-2-1, VDE 0664 Part 10 and 11, touch protection IP2x according to DIN VDE 0106 Part 100. Suitable for retrofitting additional devices (tool-free installation). Connection terminals with wire insertion protection, Bi-Connect terminals at the bottom, external blue test button. All products with VDE mark. Labeling option directly on the device.

The HAG CDH463D residual current circuit breaker is a highly advanced safety device designed for use in electrical installations. With a four-pole configuration and a rated current of 63 A, this circuit breaker provides reliable protection against fault currents of up to 30 mA. It meets the requirements of DIN EN 61008-2-1 and VDE 0664 Part 10 + 11, making it a safe choice for various applications. The switch is short-circuit resistant and offers touch protection according to IP2x, ensuring additional safety. Installation is straightforward on a DIN rail, and the retrofitting of additional devices can be done without tools. The connection terminals are equipped with wire-insertion protection, facilitating installation and handling. Additionally, the switch features an external test button that allows for a quick functionality check. With the option for labeling directly on the device, identification and usage are further simplified.
- Short-circuit resistance for increased safety
- Easy installation on DIN rail without tools
- External test button for quick functionality check
- Wire-insertion protection on the connection terminals
- VDE certified for added reliability.

Hager HAG CDH463D Residual current circuit breaker 4P 63A 30mA H I Type
The Hager CEB663E is a highly advanced residual current circuit breaker specifically designed for use in electrical installations. With a rated voltage of 400 volts and a rated current of 63 amperes, this 4-pole switch provides reliable protection against fault currents. It meets the stringent requirements of relevant standards, including DIN EN 61008-1 and DIN VDE 0100-410, making it suitable for use in modern electrical systems. The CEB663E is a type B all-current sensitive switch that detects both smooth direct current and alternating current fault currents in the frequency range up to 2 kHz. This makes it ideal for applications where both AC and DC fault currents may occur. The tool-free installation and the option for labeling directly on the device enhance user-friendliness and flexibility during installation.
- All-current sensitive residual current circuit breaker type B
- Complies with standards DIN EN 61008-1 and DIN VDE 0100-410
- Short-time delayed RCD for frequencies up to 2 kHz
- Easy tool-free installation thanks to Bi-Connect terminals
- External test button and operational indicator for easy operation.