Top rated Residual-current devices

Here’s a ranking of the top rated Residual-current devices. To give you a quick overview, we’ve added the most important information about each product. This page always stays fresh and updates automatically.

1. Hager CDA440D

Hager RCD Switch CDA440D

Manufacturer: Hager
Designation: RCD Switch 4-pole 40A/30mA, 6kA
Type: CDA440D
Number of Poles: 4
Rated Voltage: 400 V
Rated
Current: 40 A
Rated Residual Current: 0.03 A
Rated Insulation Voltage Ui: 500 V
Rated Impulse Voltage Uimp: 4 kV
Power Loss: 6.5 W
Mounting Type: DIN Rail
Residual Current Type: A
Selective Type: No
Time-Delayed Type: No
Short-Circuit Strength (Icw): 6 kA
Surge Current Strength: 0.25 kA
Voltage Type: AC
With Locking Mechanism: Yes
Frequency: 50 Hz
Additional Devices Possible: Yes
Protection Class (IP): IP20
Width in Division Units: 4
Installation Depth: 70 mm
Ambient Temperature During Operation: -25..40 °C
Degree of Pollution: 2
Connectable Conductor Cross-Section Multi-Wire: 1..16 mm²
Connectable Conductor Cross-Section Single-Wire: 1..25 mm²
RAL Number (similar): 7005
Explosion-Proof: No

Hager RCD Switch CDA440D: Additional Details
4-pole residual current circuit breaker 6kA 40A 30mA Type A. Residual current protective switch (RCD) according to DIN EN 61008-1 (VDE 0664-10), DIN EN 61008-2-1 (VDE 0664-11) with Bi-Connect terminals at the bottom, external blue test button, and residual current indicator. Suitable for retrofitting additional devices. Connection terminals with wire insertion protection, labeling option directly on the device.
 

2. Hager Circuit breaker

Hager miniature circuit breaker MBN520

Manufacturer: Hager
Designation: Miniature circuit breaker 1p+N, B-20A, 6kA
Type: MBN520
Installation depth: 70 mm

Tripping characteristic: B
Number of poles (total): 2
Number of fused poles: 1
Rated current: 20 A
Rated voltage: 230 V
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
Rated breaking capacity Icn to EN 60898 at 230 V: 6 kA
Voltage type: AC
Rated breaking capacity Icu to IEC 60947-2 at 230 V: 10 kA
Frequency: 50-60 Hz
Energy limitation class: 3
Flush-mounted: Yes
Switching neutral conductor: Yes
Overvoltage category: 3
Degree of pollution: 2
Additional devices possible: Yes
Width in pitch units: 2
Protection class (IP): IP20
Ambient temperature during operation: -25 to 70 °C
Connectable conductor cross-section stranded: 1 to 25 mm²
Connectable conductor cross-section solid: 1 to 35 mm²
Explosion-proof: No

Hager miniature circuit breaker MBN520: further details
Miniature circuit breaker 1P+N 6kA B-characteristic 20A 2 modules. Miniature circuit breaker to DIN EN 60898-1, contact protection IP2x to DIN VDE 0106 Part 100 with VDE symbol. LS with time-delayed thermal release for overload protection and electromagnetic release for short-circuit protection. Suitable for retrofitting of additional devices. Labelling option directly on the unit and individual removal from the busbar system by unlocking the top-hat rail quick-release fastening.
 

3. ABB RCD, F 202, 2 POLE

ABB Stotz S&J RCD F202A-25/0.03

Manufacturer: ABB Stotz S&J
Designation: RCD pro M Compact
Type: F202A-25/0.03
Number of Poles: 2
Rated Voltage: 230 V

Rated Current: 25 A
Rated Residual Current: 0.03 A
Rated Insulation Voltage Ui: 500 V
Rated Impulse Voltage Uimp: 4 kV
Mounting Type: DIN Rail
Residual Current Type: A
Selective Type: No
Short-time Delay Type: No
Short-Circuit Strength (Icw): 1 kA
Surge Current Strength: 0.25 kA
Type of Voltage: AC
With Locking Mechanism: Yes
Frequency: Other
Additional Devices Possible: Yes
Protection Class (IP): IP20
Width in Division Units: 2
Installation Depth: 69 mm
Ambient Temperature During Operation: -25..55 °C
Degree of Pollution: 2
Connectable Conductor Cross-Section Multistranded: 0..25 mm²
Connectable Conductor Cross-Section Solid: 25 mm²
Explosion-Proof: No

ABB Stotz S&J RCD F202A-25/0.03: Additional Details
Residual Current Devices (RCDs) provide protection for persons and property as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. The F200 series RCDs ensure protection against sinusoidal alternating currents and pulsating currents with a smooth direct residual current component of up to 6 mA to ground. They also provide fault protection (protection against indirect contact), additional protection (with I?n = 30 mA), and fire protection (with I?n = 300 mA). They comply with product standards IEC/EN 61008-1, 61008-2-1, 61543 (VDE 0664 10, 11, 30) and for F200 A up to 100 A UL 1053. Areas of application include household, commercial, and industrial uses. The extensive range of accessories provides everything you need for your installation tasks. Numerous approvals make the F200 suitable for worldwide use. EAN: 8012542782506.
 

4. ABB RCD, F 202, 2 POLE

Current: 25A
Number of poles: 2
Tripping sensitivity: 300mA
Tripping characteristic: Type A
Series: F202

This residual current device (RCD) from the F200
series complies with DIN VDE 0664 Part 11, DIN VDE 0664 Part 1, and EN 61008-2-1. It detects both AC fault currents and pulsating DC fault currents. It is short-circuit proof up to 250A, making it insensitive to brief leakage currents to ground. It features DIN rail mounting and includes a signal contact/helper switch with a changeover switch. A maximum of three S2C-S/H6R units can be mounted side by side. 

5. ABB RCD, F 202, 2 POLE

Current: 40A
Number of poles: 2
Tripping sensitivity: 300mA
Tripping characteristic: Type A
Series: F202

This residual current circuit breaker (RCD) from
the F200 series complies with DIN VDE 0664 part 11, DIN VDE 0664 part 1, and EN 61008-2-1 standards. It captures AC residual currents as well as pulsating DC residual currents. It is surge current resistant up to 250A, making it insensitive to short leakage currents to earth. Designed for DIN rail mounting, it includes a signal contact/auxiliary switch with one changeover contact. A maximum of three S2C-S/H6R units can be lined up. 

6. Schneider Electric Residual current circuit breaker

Rated current: 40 A. Tripping sensitivity: 30mA. Rated AC voltage: 400 V, 415 V. DIN rail mounting. Range: Acti 9. tripping time: instantaneous. Series: iID. Acti9 iID residual current circuit-breaker. The Acti 9 iID RCDs for DIN rails are fully coordinated with the iC60 moulded-case circuit-breakers to ensure complete protection of people and equipment against electric shock and fire, as well as improved continuity of operation. iID AC type RCDs provide:. Protection against electric shock on direct contact (≦ 30 mA). Protection against electric shock on indirect contact (≦ 100 mA). Protection of fixtures against fire (300 mA or 500 mA). iID-FI overload switches type Asi provide the following:. Protection against electric shock on direct contact (≦ 30 mA). Protection against electric shock with indirect contact (≦ 300 mA). Protection of fixtures against fire (300 mA or 500 mA). Increased immunity to electrical interference and contaminated or corrosive environments. 

7. Hager FI/LS switch

Residual current circuit breaker according to DIN EN 61009-1 (VDE 0664-20) with QuickConnect connection, up to 20 A on the supply line and up to 63 A on the supply line, blue test button and residual current display. Easy individual removal from the phase busbar system. Suitable for retrofitting additional devices. Labeling option directly on the device. 

8. Hager FI/LS 4Pol. 3P+N 32A/30mA

The combined residual current circuit breaker from Hager, model FI/LS 4Pol. 3P+N 32A/30mA, offers a reliable solution for the protection of electrical installations. With a tripping characteristic of class C, this switch is ideal for applications that require a delayed response to overload currents. The switch is designed for mounting on a DIN rail and features a compact design that allows for easy installation. A test button and a residual current indicator through a blue display window provide additional safety and user-friendliness. The switch is rated for a nominal voltage of 400 V and offers a rated current of 32 A, making it a robust choice for various electrical systems.

- Combination of residual current and circuit breaker
- Test button for easy functionality check
- Residual current indication via blue display window
- Suitable for mounting on DIN35 rail
- Protection class IPX2 for additional moisture protection.
 

9. Hager HAG ADS963D

The HAG ADS963D Fi-LS 1P+N 6kA C-13A 30mA Type A QC from Hager is a highly developed residual current circuit-breaker that offers protection against both overload and residual currents. With a rated current of 13 A and a rated residual current of 30 mA, this device is ideal for use in residential and commercial installations. The switch is equipped with a QuickConnect terminal for quick and easy installation. It fulfils the requirements of DIN EN 61009-1 and offers a high level of contact protection in accordance with DIN VDE 0106 Part 100. The blue test button and the residual current indicator ensure user-friendly handling and safety. In addition, the labelling option directly on the device enables clear marking, which makes maintenance and identification easier. 

10. ABB RCD, F 204, 4 POLE

Current: 25A
Number of poles: 4
Trigger sensitivity: 300mA
Tripping characteristic: Type A
Series: F204

DIN VDE 0664 part 11, DIN VDE 0664 part 1, EN
61008-2-1. Residual current circuit-breaker, series F200. This device provides 2- or 4-pole AC fault current detection as well as pulsating DC fault currents. It is surge current resistant up to 250A and is thus insensitive to short leakage currents to earth. Designed for DIN rail mounting, it includes a signal contact/auxiliary switch with 1 change-over contact. A maximum of three S2C-S/H6Rs can be connected in series. 

Product order