RCBOs combine residual current and circuit breakers in one device (RCCB/MCB combination). They protect people from residual currents and installations from short circuits and overloads. The DRCBO 4 has a rated breaking capacity of 6 kA. In addition to a trip indicator, it also features a labeling window. Type A switches are sensitive to pulsating and alternating currents. This function is independent of the mains voltage. Switches with characteristic B are the standard protection for lighting and socket circuits. Standard switches are designed for circuits with a rated voltage of 230 V or 400 V and a rated frequency of 50 Hz. Features: pulsating and alternating current sensitivity, mains voltage-independent tripping, compact size for all rated currents, switching position indicator, separate indication of the tripping cause, terminal blocks with a wide clamping cross-section range on both connection sides, neutral conductor on the right, labeling window, mounting type: quick fastening on mounting rail, installation position arbitrary, supply arbitrary. Areas of application: protection of circuits in residential and commercial buildings as well as industrial plants with TN-S, TT, and TN-C-S networks. In IT networks, RCCB/MCB switches can be provided for disconnection in the event of a second earth fault. Use in systems with TN-C networks and for the protection of circuits where power electronics equipment can cause smooth direct fault currents or fault currents with frequencies other than 50/60 Hz is excluded.
Circuit breaker type | Miniature circuit-breaker/residual current circuit-breaker combination |
Length | 68 mm |
Width | 4 mm |
number of poles | 4 |
Mounting type | Top-hat rail |
Item number | 36785846 |
Manufacturer | Doepke |
Category | Residual-current device |
Manufacturer no. | 09945106 |
Release date | 28/6/2023 |
Circuit breaker type | Miniature circuit-breaker/residual current circuit-breaker combination |
Mounting type | Top-hat rail |
Mounting type | Engagement |
number of poles | 4 |
Tripping characteristic | B |
Rated current | 25 A |
Rated current | 0.03 A |
Rated voltage | 400 V |
voltage type | AC |
Rated insulation voltage Ui | 440 V |
Residual current (rated differential current) | 0.03 A |
Protection type (IP code) | IP20 |
Country of origin | Italy |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 68 mm |
Width | 4 mm |
Height | 68 mm |
Product Safety |
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: GalaxusHow many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: GalaxusUnfortunately, we don't have enough data for this category yet.
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus