Hager Helicopter 3 + N AC Switch B 10A 0.03A Type A 6kA Type RCBO (ADZ310D)
Here's a ranking of the best products in this category. To give you a quick overview, we've also added some key information about the products.
Residual current circuit breaker 3X 1PN 6kA B-10A 30mA Type QuickConnect. Residual current circuit breaker according to DIN EN61009-1 VDE 0664-20 with a single-pole circuit breaker for 230V AC circuits and a residual current protection circuit in a compact housing. QuickConnect terminal according to DIN EN 60898-1 VDE 0641-11, with a load capacity of up to 16 A at the output and up to 63 A at the input, blue test button, and residual current indicator. Easy individual removal from the phase rail connection. Suitable for retrofitting additional devices. Labeling option directly on the device. ADZ310D.
Hager Helicopter 3 + N AC Switch B 10A 0.03A Type A 6kA Type RCBO (ADZ310D)
Range: Acti 9
Series: iMX
Type: Shunt release
Control voltage: 100 to 415 V AC, 110 to 130 V DC
Auxiliary contacts: Auxiliary electrical components are combined with iC60 circuit breakers, iID residual current circuit breakers, iSW-NA remotely tripped disconnect switches, RCA remote controls, and ARA automatic make contacts. They provide trip or remote indication of their position (open/closed/tripped) in the event of a fault.
Tripping auxiliary components:
- iMN: Undervoltage release
- iMNs: Undervoltage release with delay
- iMNx: Undervoltage release, independent of supply voltage
- iMX: Shunt release
- IMX + OF: Shunt release with NC/NO contact
Indicator auxiliary components:
- iOF: Normally closed/normally open contact
- iSD: Fault indication contact
- IOF/SD + OF: Normally closed/normally open contact and switchable OF or SD contact.
Hager RCD CDA440D
Manufacturer: Hager
Designation: 4-pole RCD 40A/30mA, 6kA
Type: CDA440D
Number of poles: 4
Rated voltage: 400 V
Rated current: 40 A
Rated residual current: 0.03 A
Rated insulation voltage Ui: 500 V
Rated impulse voltage withstand Uimp: 4 kV
Power loss: 6.5 W
Mounting type: DIN rail
Residual current type: A
Selective type: no
Time-delayed type: no
Short-circuit strength (Icw): 6 kA
Surge current strength: 0.25 kA
Voltage type: AC
With locking device: yes
Frequency: 50 Hz
Additional devices possible: yes
Protection class (IP): IP20
Width in division units: 4
Installation depth: 70 mm
Ambient temperature during operation: -25..40 °C
Degree of pollution: 2
Connectable conductor cross-section multi-stranded: 1..16 mm²
Connectable conductor cross-section single-stranded: 1..25 mm²
RAL number (similar): 7005
Explosion-proof: no
Hager RCD CDA440D: additional details
4-pole residual current circuit breaker 6kA 40A 30mA Type A. Residual current circuit breaker (RCD) according to DIN EN 61008-1 (VDE 0664-10), DIN EN 61008-2-1 (VDE 0664-11) with Bi-Connect terminals at the bottom, external blue test button, and residual current indicator. Suitable for retrofitting additional devices. Connection terminals with wire insertion protection, labeling option directly on the device.
Legrand miniature circuit-breaker 404098
Manufacturer: Legrand
Designation: Miniature circuit-breaker B16A 1-pole + N 10kA
Type: 404098
Mounting depth: 44 mm
Tripping characteristic: B
Number of poles (total): 2
Number of fused poles: 1
Rated current: 16 A
Rated voltage: 230 V
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
Rated breaking capacity Icn according to EN 60898 at 230 V: 10 kA
Voltage type: AC
Frequency: 50-60 Hz
Energy limitation class: 3
Flush mounting: Yes
Switching neutral conductor: Yes
Degree of pollution: 2
Additional devices possible: Yes
Width in pitch units: 2
Protection class (IP): IP20
Explosion-proof: No
Legrand miniature circuit-breaker 404098: further details
Legrand miniature circuit-breaker TX3 to EN 60898-1, VDE 0641-11, EN 60947-2, 1-pole with connecting neutral, B-characteristic, rated current In 16 A, rated breaking capacity Icn 10 kA to EN 60947-2. Icn 10 kA according to EN 60898-1, rated voltage Un 230 VAC, rated frequency 50/60 Hz, energy limitation class 3, mounting on DIN rail EN 60715 by means of a latching quick-release fastening, clear information on the front of each unit, clear switch position information on the front of each unit, clear red/green switch position indication on the switch lever, with labelling window, with plug-in protection for safe insertion of the conductor into the lift terminal, mounting of auxiliary devices possible. Miniature circuit breakers with B characteristic are primarily intended for line protection in lighting and socket circuits.
EAN: 3414970392138.
Residual current circuit breaker 4P 10kA B-20A 30mA Type A. Residual current circuit breaker according to DIN EN 61009-1 VDE 0664-20 with a 4-pole circuit breaker for 400 three-phase circuits and a residual current protection circuit in a compact housing, blue test button, and residual current indicator. Easy single removal from the phase rail connection. Suitable for retrofitting additional devices. Labeling option directly on the device. ADX420D.
Residual current circuit breaker according to DIN VDE 0664-20 / EN61009-1 with 3 x 1-pole miniature circuit breakers for 230 V AC circuits and a residual current circuit breaker in a compact housing. QuickConnect connection according to DIN EN 60898-1, VDE 0641-11, for supply lines up to 16 A and for supply lines up to 63 A, touch protection according to IP2x DIN VDE 0106 Part 100, blue test button and residual current indicator. Easy individual removal from the phase busbar system. With VDE symbol. Suitable for retrofitting additional devices. Labeling option directly on the device.
The M9R81225 M9 GFP 2P 25A 26MA Type A-SI 120/240V residual current circuit breaker from Schneider Electric is a highly advanced residual current device designed for use in various electrical applications. This circuit breaker provides reliable protection against electric shocks from direct and indirect contact, as well as effective protection for electrical installations in the event of insulation faults. With a rated current of 25A and an operating voltage of 120-240V, this circuit breaker is ideal for use in damp or aggressive environments. The tripping unit technology is based on differential current, ensuring high immunity to transient leakage currents. The M9R81225 complies with relevant standards, including IEC/EN 61008-1 and UL 1053, providing high safety and reliability in application.
- Two-pole residual current circuit breaker with 25A rated current
- Type A-SI for enhanced safety in damp environments
- High electrical immunity to transient leakage currents
- Complies with international standards such as IEC/EN 61008-1 and UL 1053
- Suitable for use in aggressive environments.
Schneider Electric M9R81225 M9 GFP 2P 25A 26MA TYPE A-SI 120/240V circuit breaker
Acti 9 iC60N circuit breaker, 6kA (IEC/EN 60898-1), 50kA (IEC/EN 60947-2). Single-pole, rated current 1A, B-characteristic, operating voltage (Ue) 220-240V AC, insulation voltage (Ui) 500V AC. Double connection terminal for cables and pin busbar at the top and bottom of the device. Jump switching for wear-free operation of the contacts. Moving insulation cover. Operation of the DIN rail mounting element on the front side of the device for tool-free assembly and easy accessibility for the user. With mechanical front-facing fault indication (VisiTrip) to show tripping due to overload or short circuit. Safe contact indication (VisiSafe) of the circuit breaker, with a green indication ensuring voltage-free safety on the outgoing side. Terminals IP20, moving insulation cover. Double connection terminal from above or below. Easy removal of the individual device when the phase busbar is installed, thanks to the front-accessible mounting element. Technology of the tripping unit - thermomagnetic. Compatible with the residual current devices of the Acti 9 iID series as well as the Vigi iC60 residual current block. Additional snap-on auxiliary modules (optional) - indication of switching position, fault tripping, working current tripping, undervoltage tripping, overvoltage tripping. Colour shade RAL 9003. The iC60N circuit breaker complies with the following standards - IEC/EN 60898-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified. Circuit breaker, automatic fuse, MCB, short circuit protection, overload protection, short circuit.
ABB Stotz S&J Contactor AF12-30-10-11
Manufacturer: ABB Stotz S&J
Designation: Contactor 24-60 50/60 20-60VDC
Type: AF12-30-10-11
Rated control supply voltage Us at AC 50 Hz: 24 V
Rated control supply voltage Us at AC 60 Hz: 24 V
Rated control supply voltage Us at DC: 20 V
Type of voltage for actuation: AC/DC
Rated operational current Ie at AC-1, 400 V: 28 A
Rated operational current Ie at AC-3, 400 V: 12 A
Rated operational power at AC-3, 400 V: 5.5 kW
Rated operational power NEMA: 3.72849999 kW
Suitable for rail mounting: no
Number of auxiliary contacts as normally open: 1
Connection type main circuit: screw connection
Number of normally open contacts as main contacts: 3
The 3-pole AF12 contactors represent a compact series with AC/DC control and very wide coil voltage ranges. They switch power circuits with motors, lightly inductive or non-inductive loads. Only 4 coils cover control voltages from 20...500 VDC to 24...500 VAC. They feature integrated surge protection and do not require additional suppression components. All integrated or retrofittable normally open auxiliary contacts are designed as mirror contacts according to IEC60947-5-1 Annex L. Additional accessories such as time relays, wiring aids, and interlocking components complement the range. Contactors with the coil code -11 are not suitable for connection to 24V DC PLC outputs.
EAN: 3471523110311.
The Hager CEC425J is a residual current protection block designed to protect electrical systems from hazardous fault currents. This protective switch is an essential component in electrical installations, as it helps minimize the risk of electric shocks and fires. With a high rated insulation voltage of 400 volts and a rated current of 25 amperes, the CEC425J offers a reliable solution for various applications. The residual current protection block is designed for use in alternating current systems and features a pole count of 4, making it versatile. Its compact design allows for easy integration into existing switch cabinets and installations.
- Rated fault current of 0.1 A for enhanced safety
- Fault current of 100 mA to prevent overloads