
Best selling Residual-current devices from Legrand
This page always stays fresh and updates automatically.
1. Legrand Circuit breaker
Legrand miniature circuit-breaker 404098
Manufacturer: Legrand
Designation: Miniature circuit-breaker B16A 1-pole + N 10kA
Type: 404098
Mounting depth: 44 mm
Tripping characteristic: B
Number of poles (total): 2
Number of fused poles: 1
Rated current: 16 A
Rated voltage: 230 V
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
Rated breaking capacity Icn according to EN 60898 at 230 V: 10 kA
Voltage type: AC
Frequency: 50-60 Hz
Energy limitation class: 3
Flush mounting: Yes
Switching neutral conductor: Yes
Degree of pollution: 2
Additional devices possible: Yes
Width in pitch units: 2
Protection class (IP): IP20
Explosion-proof: No
Legrand miniature circuit-breaker 404098: further details
Legrand miniature circuit-breaker TX3 to EN 60898-1, VDE 0641-11, EN 60947-2, 1-pole with connecting neutral, B-characteristic, rated current In 16 A, rated breaking capacity Icn 10 kA to EN 60947-2. Icn 10 kA according to EN 60898-1, rated voltage Un 230 VAC, rated frequency 50/60 Hz, energy limitation class 3, mounting on DIN rail EN 60715 by means of a latching quick-release fastening, clear information on the front of each unit, clear switch position information on the front of each unit, clear red/green switch position indication on the switch lever, with labelling window, with plug-in protection for safe insertion of the conductor into the lift terminal, mounting of auxiliary devices possible. Miniature circuit breakers with B characteristic are primarily intended for line protection in lighting and socket circuits.
EAN: 3414970392138.

2. Legrand LS C16A 3P 6KA 3M Miniature circuit-breaker
The RX3 circuit breaker with C-characteristic from Legrand is a reliable and safe device designed for the protection of electrical circuits. With a rated current of 16 A and a nominal voltage of 400 VAC, this 3-pole circuit breaker is particularly suitable for applications where high inrush currents occur, such as with motors and transformers. The breaker complies with the standards EN 60898-1 and VDE 0641-11 and offers a rated breaking capacity of 6 kA, making it a robust choice for various electrical installations. Installation is straightforward on a DIN rail, and the clear labeling of the switching positions ensures user-friendly handling. The RX3 circuit breaker is also equipped with a labeling field for personalized identification.
- Energy limitation class 3 for additional protection
- Thermal-magnetic tripping for reliable operation
- Suitable for flush mounting
- Clear switching position indication for easy operation
- Manufactured in France to high quality standards.

3. Legrand Circuit breaker Tx3 403387 Ls B16A 2P 6Ka 2M 403387
The TX3 circuit breaker with B-characteristic from Legrand is a reliable and safe device designed for use in electrical installations. With a rated current of 16 A and a rated voltage of 400 V, this two-pole protective switch provides effective protection against overload and short circuits. The switch meets the requirements of the standards EN 60898-1 and VDE 0641-11 and is suitable for mounting on a DIN rail. The energy limitation class 3 ensures high safety and reliability in operation. The TX3 is equipped with a clear switching position indicator, allowing for easy operation. Additionally, it offers the option to attach auxiliary devices, increasing flexibility in application. The protective switch is suitable for use in environments with a pollution degree of 2 and has an IP20 protection rating, which protects it from solid foreign objects. With its robust design and thoughtful features, the TX3 circuit breaker is an excellent choice for various electrical applications.
- Two-pole circuit breaker with B-characteristic
- Energy limitation class 3 for increased safety
- Clear switching position indicator in red/green
- Mounting on DIN rail with snap-on quick fastening
- Compatible with auxiliary devices for extended functionality.

4. Legrand 403388
Circuit breaker S302 B20 TX3 20A 6kA 403388. Double pole circuit breaker S 302. Rated voltage: 400V AC. Protection class: IP2x. Mounting: TH35 rail. Colour: grey RAL 7035. Rated current: 20 A. Characteristics: Short circuit A power 6. Maximum voltage: 440 V AC. Mechanical life: 20,000 movements. Rated frequency: 50 to 60 Hz. Number of poles: 2. Insulation voltage: 500 V. Electrical life: 4000 operations. Minimum voltage: 12 V AC.

5. Legrand Circuit breaker Tx3 Ls C2A 1P 6Ka1M 403427
The TX3 circuit breaker with C-characteristic from Legrand is a reliable protective device specifically designed for use in electrical installations. With a rated current of 2 A and a nominal voltage of 230/400 VAC, this single-pole circuit breaker provides effective protection against overload and short circuits. It meets the requirements of the standards EN 60898-1 and VDE 0641-11 and is suitable for applications where high inrush currents occur, such as with motors and transformers. The switch is equipped with an energy limitation class 3 and features a clear switching position indicator as well as a labeling window for easy identification. Installation is straightforward on a DIN rail, facilitating integration into various electrical systems.
- Energy limitation class 3 for additional protection
- Clear switching position indicator in red/green
- Quick mounting on DIN rail for easy installation
- Plug-in protection for safe insertion of the conductor
- Mounting of auxiliary devices possible.

6. Legrand Circuit breaker Tx3 403403 Ls B20A 3P 6Ka 3M 403403
The TX3 circuit breaker with B-characteristic from Legrand is a reliable and safe device developed according to the standards EN 60898-1 and VDE 0641-11. This 3-pole protective switch is designed for a rated current of 20 A and offers a rated breaking capacity of 6 kA. It is ideal for use in lighting and socket circuits, ensuring effective line protection. The switch is designed for a rated voltage of 400 VAC and a rated frequency of 50/60 Hz. Installation is straightforward on a DIN rail, and the clear indication of the switching position along with the labeling window ensures user-friendly handling. The TX3 circuit breaker is also equipped with a terminal protection feature that allows for safe insertion of the conductor into the terminal block. These features make it an excellent choice for various electrical installations.
- Energy limiting class 3 for additional protection
- Locking quick-mounting for easy installation
- Clear switching position indication in red/green
- Mounting of auxiliary devices possible
- Protection class IP20 for indoor use.

7. Legrand 409842
The Legrand circuit breaker 409842 is a highly advanced electrical protection device specifically designed for use in power circuits. With a D characteristic, this breaker is ideal for applications that require high inrush currents, such as welding transformers. The breaker complies with the EN 60947-2 standard and offers reliable performance with a rated current of 125 A and a rated breaking capacity of 25 kA. Installation is straightforward on a DIN rail, making setup easier. Additionally, the breaker features a clear switching position indicator in red/green and a labeling window for easy identification. The plug-in protection ensures added safety when inserting the conductor into the terminal block. With the option to mount auxiliary devices, this circuit breaker provides flexibility for various applications.
- D characteristic for high inrush currents
- Clear switching position indicator in red/green
- Mounting on DIN rail with quick fastenings
- Plug-in protection for safe conductor insertion
- Option to mount auxiliary devices.

8. Legrand TX3 miniature circuit-breaker
The TX3 miniature circuit-breaker with C characteristic from Legrand is a reliable protective device that has been specially designed for use in electrical installations. It fulfils the EN 60898-1, VDE 0641-11 and EN 60947-2 standards and offers a rated current of 16 A and a rated breaking capacity of 6 kA. With a rated voltage of 400 VAC and a frequency of 50/60 Hz, this switch is ideal for applications that require high inrush currents, such as motors and transformers. The switch is suitable for mounting on a top-hat rail and has a snap-in quick-release fastening for easy installation. A clear switching position indicator in red/green and a labelling window ensure user-friendly handling. The TX3 miniature circuit-breaker is also equipped with an under-plug protection that ensures safe insertion of the conductor into the lift terminal. In addition, auxiliary devices can be attached, which increases the flexibility and functionality of the device. Energy limitation class 3 for improved protection. Clear switching position indicator for easy operation. Under-plug protection for safe insertion of the conductor. Mounting on top-hat rail with snap-in quick fastening. Attachment of auxiliary devices possible.

9. Legrand Dx3 FI/LS switch C16A 1P+N 411061 6Ka 30Ma A 411061
DX3 RCD/MCB, C-curve, 16A, single pole with switched neutral, 6kA, 30mA, Type A, 230VAC, 2 modular units, 411061.
Optimal protection: The DX3 Type A RCD/MCB is the perfect solution to make your electrical installations safer. The switch provides protection against alternating and pulsating DC fault currents.
Residual current circuit breaker: The instantaneous Type A residual current circuit breaker immediately detects even the smallest deviations, thus protecting your circuit by instantly disconnecting your installation.
Tripping indicator: The easily visible tripping indicator provides you with immediate feedback on the switching status. It distinguishes between yellow (fault current or test button tripping) and white (short circuit or manual tripping).
Circuit breaker: The C-curve circuit breaker keeps your circuit flowing steadily, ensuring lasting safety in various applications by minimizing disturbances.
User-friendly: The RCD/MCB is user-friendly, thanks to the clear red/green switching position indicator on the switch lever (lockable) and the clearly readable labeling window.
Installation: You can easily install the RCD/MCB on a DIN rail EN 6715 using a snap-on quick fastening system and add additional auxiliary devices as needed.
Technical details: 25A short-circuit withstand, 230V rated voltage, 50Hz rated frequency, 30mA rated residual current, 16A rated current, 2 modular dimensions (17.5mm).

10. Legrand 404243
The Legrand TX3 circuit breaker is a reliable and safe device designed according to the standards EN 60898-1, VDE 0641-11, and EN 60947-2. With a C characteristic, this 3-pole switch is ideal for applications that require high inrush currents, such as motors and transformers. The switch has a rated current of 40 A and a rated breaking capacity of 10 kA, making it a robust choice for circuit protection. Installation is straightforward on a DIN rail, and the clear switching position indicator along with the labeling window ensures user-friendly handling. Additionally, the plug-in protection guarantees safe insertion of the conductor into the terminal block. The TX3 is designed for use in AC voltage applications with a rated voltage of 400 V and offers a high insulation voltage of up to 500 V.
- 3-pole with a switching neutral conductor
- Energy limiting class 3
- Snap-on quick mounting for easy installation
- Clear switching position indicator in red/green
- Mounting of auxiliary devices possible.
